Leakage in hydraulic check valves troubled Cuenca for 2 years, and AAK solved it

$ 30 /unidad
IVA no incluido
Cantidad mínima: 100 unidades
Tiempo de entrega: 3 meses
Envío a: Todo el mundo
Descripción de

Leakage in hydraulic check valves troubled Cuenca for 2 years, and AAK solved it

:
Cuenca is a senior purchaser of AGRIA company in Spain. The boss is very satisfied with his purchasing work. Two years ago, AGRIA company developed a hydraulic equipment, and there were complaints after sales for more than half a year. The main problem was that the starting force of the hydraulic system would be insufficient, which was caused by the increase of internal leakage of the hydraulic check valves in the equipment. After Cuenca contacted the original hydraulic check valve manufacturer, the manufacturer said that some hydraulic check valves may have deviation during assembly, and he was willing to replace the hydraulic check valves with large leakage with new ones. Cuenca thought it was completely solved after replacement, but what surprised him was that less than a year after the new hydraulic check valve was replaced, the same problem occurred again. The boss was very disappointed with his purchase of hydraulic check valves this time.

The manufacturer of the original hydraulic check valves still said that except for replacing the hydraulic check valves, there is no other way. Cuenca began to worry that if the same problem happened a third time, it would be too shameless. To be safe, he began to look for a new supplier of hydraulic check valves and began to test samples. At the same time, he also wanted to know why the hydraulic check valves produced by the original manufacturer leaked. In this way, Cuenca contacted AAK hydraulic valve.

After several rounds of communication with Cuenca, we learned the story between him and the original manufacturer of hydraulic check valves, and suggested him to send us the hydraulic check valves with problem and provide us the drawings of hydraulic check valves at the same time. AAK engineer disassembled the hydraulic check valves of the original manufacturer and found that there were wear marks on the sealing line on the surface of the poppet valve. When the pressure oil reversely enters the hydraulic check valve, the cone cannot strictly seal the oil and cause leakage, and some oil flows out of the oil inlet. After receiving AAK's analysis, Cuenca asked us to make 4 samples of hydraulic check valves according to his drawings.

Our engineers designed a new hydraulic check valve according to the service frequency and working conditions of the equipment, replacing the cone valve with the ball valve. The cone valve is prone to fatigue creep deformation and wear after working for a long time, resulting in a gap between the valve sleeve and the cone, resulting in leakage. The outer circle of the ball valve can contact the inner taper ring line, and the connecting hole can be closed to reduce the leakage caused by wear. Cuenca was surprised that AAK dared to take the initiative to modify the drawings of their hydraulic check valves, and expected to see the sample performance of AAK hydraulic check valves.

Two months later, AAK sent samples of the newly designed hydraulic check valves. A year later, Cuenca said that the hydraulic equipment equipped with AAK hydraulic check valves had no complaints about startup.