Ultrasonic Generator Specifications:
Frequency: 1.0 MHz 5%
3.2 MHz 5%
3.3 MHz 5%
Modes: Continuous
Pulsed—20% duty cycle
Pulsed—50% duty cycle
Modulation: 100%
Modulation Waveform: Rectangular
Pulse Repetition Rate:
Modulation Frequency
100 Hz 20%
Pulse Duration:
Modulation Period
2 msec 20%, 20% duty cycle
5 msec 20%, 50% duty cycle
Temporal Peak/ average
intensity ratio:
5:1 20%, 20% duty cycle
2:1 20%, 50% duty cycle
Maximum output power: 22 w with a 10 cm applicator, (me 7310)
11 w with a 5 cm applicator, (me 7513)
2.2 w with a 1 cm applicator (me 7331)
Maximum intensity: 2.2 w/cm with all applicators
Indication accuracy: 20% (for any level above 10% of maximum)
Output description: The output waveform is continuous or pulsed as programmed
by the membrane panel control. In the pulse mode the 1, 3.2
or 3.3 MHz square wave pulses
are modulated. The power level is adjusted by varying the
pulse amplitude. The pulse waveforms are shown
below:
Time
Output
1, 3.2 or 3.3 MHz
Ultrasound
Pulse Width
2 ms
Pulse Space
10 ms
Figure 3.1—Pulse Waveform—20% Duty Cycle
Time
Output
1, 3.2 or 3.3 MHz Ultrasound
Pulse Width
5 ms
10 ms
Pulse Space
Waveform Specifications:
Interferential Mode
Figure 3.8—
Interferential Waveform
Waveform Type: Sinewave
Polarity: None
Volts: 0-65 volts rms, 1 Kohm load
Current: 0-65 mA rms, 1 Kohm load
Average current at
maximum intensity
and frequency: 65 mA rms
Maximum current
density under 2"
diameter electrode. 3.2 mA/cm Frequency: Channel 1 = 4000 Hz
Channel 2 = 4000 to 4250
Hz variable frequency sine wave
Frequency Modulation: 1-15 Hz
80-150 Hz
1-150 Hz
xx-xx Hz,
xx=any value from
1 to 250 Hz
Phase Duration: 125 μs
Available Amplitude
Modulation Options: Vector rotation
Available Channels: Channel pairs 1 & 2 or 3 &4
Premodulated Mode
Figure 3.9—Premodulated
Waveform
Waveform Type: Amplitude modulated
sine wave
Polarity: None
Volts: 0-50 volts rms, 1 Kohm load
Current: 0-50 mA rms, 1 Kohm load
Average current at
maximum intensity
and frequency: 50 mA rms
Frequency: 1.0 MHz 5%
3.2 MHz 5%
3.3 MHz 5%
Modes: Continuous
Pulsed—20% duty cycle
Pulsed—50% duty cycle
Modulation: 100%
Modulation Waveform: Rectangular
Pulse Repetition Rate:
Modulation Frequency
100 Hz 20%
Pulse Duration:
Modulation Period
2 msec 20%, 20% duty cycle
5 msec 20%, 50% duty cycle
Temporal Peak/ average
intensity ratio:
5:1 20%, 20% duty cycle
2:1 20%, 50% duty cycle
Maximum output power: 22 w with a 10 cm applicator, (me 7310)
11 w with a 5 cm applicator, (me 7513)
2.2 w with a 1 cm applicator (me 7331)
Maximum intensity: 2.2 w/cm with all applicators
Indication accuracy: 20% (for any level above 10% of maximum)
Output description: The output waveform is continuous or pulsed as programmed
by the membrane panel control. In the pulse mode the 1, 3.2
or 3.3 MHz square wave pulses
are modulated. The power level is adjusted by varying the
pulse amplitude. The pulse waveforms are shown
below:
Time
Output
1, 3.2 or 3.3 MHz
Ultrasound
Pulse Width
2 ms
Pulse Space
10 ms
Figure 3.1—Pulse Waveform—20% Duty Cycle
Time
Output
1, 3.2 or 3.3 MHz Ultrasound
Pulse Width
5 ms
10 ms
Pulse Space
Waveform Specifications:
Interferential Mode
Figure 3.8—
Interferential Waveform
Waveform Type: Sinewave
Polarity: None
Volts: 0-65 volts rms, 1 Kohm load
Current: 0-65 mA rms, 1 Kohm load
Average current at
maximum intensity
and frequency: 65 mA rms
Maximum current
density under 2"
diameter electrode. 3.2 mA/cm Frequency: Channel 1 = 4000 Hz
Channel 2 = 4000 to 4250
Hz variable frequency sine wave
Frequency Modulation: 1-15 Hz
80-150 Hz
1-150 Hz
xx-xx Hz,
xx=any value from
1 to 250 Hz
Phase Duration: 125 μs
Available Amplitude
Modulation Options: Vector rotation
Available Channels: Channel pairs 1 & 2 or 3 &4
Premodulated Mode
Figure 3.9—Premodulated
Waveform
Waveform Type: Amplitude modulated
sine wave
Polarity: None
Volts: 0-50 volts rms, 1 Kohm load
Current: 0-50 mA rms, 1 Kohm load
Average current at
maximum intensity
and frequency: 50 mA rms
ID producto: 767866
| Referencia: 767866
| Vendido por:
Ancor Comercio Internacional
Fecha de alta del producto 29/12/2010
-
Modificado por el vendedor 15/02/2018
Productos relacionados con
Unidad combinada marca mettler mod. 994
Fotodepilacion, hair removal, depilacion machine, elight+shr
A convenir
Medical Beauty
Shr technology:Shr=Super Hair Removal, it's a revolutionary technology of hair removal which is having a sweeping success.1. Shr machine is with Single pulse mode can emit energy averagely,...
Elight IPL+RF para depilación/eliminar las arrugas/rejuvenecimiento
A convenir
Medical Beauty
Shr technology:Shr=Super Hair Removal, it's a revolutionary technology of hair removal which is having a sweeping success.1. Shr machine is with Single pulse mode can emit energy averagely,...
Elight+shr hair removal, depilacion, fotodepilacion, permanent hair removal
A convenir
Medical Beauty
The theory of Elight (ipl + rf)Advanced technologies: bipolar rf (radio frequency) + ipl(intense pulsed light), can be used together or separately. Perfect treatment results can be expected. The rf...
Diode Laser, Laser de Diode para la depilacion, fotodepilacion, laser depilacion
A convenir
Medical Beauty
Advantages1. Suitable for any color of hair2. Suitable for any kind of skin3. Diode laser hair removal is safe, fast and high efficiency4. International Hair Removal Golden Standard.5. Permanent...
China diodo láser portátil 808nm/810nm depilación definitiva
A convenir
Medical Beauty
1.Teoría808NM System uses the unique laser with long pulse width 808nm to penetrate into hair follicle.Using the theory of selective optical absorption, laser can be preferentially absorbed by the...
IPL Elight machine for hair removal, depilacion, fotodepilacion, acne removal
A convenir
Medical Beauty
Applications of Elight (ipl+rf):- shr big crystal spot size 15x50 for hair removal with super stronger energy;- ipl+rf for skin rejuvenation ,shrink pores ,wrinkle removal. photo rejuvenation with...
Ultrasonic lace sewing machine from china tc brand
$ 1,500 /ud
ChangZhou TengChao Machinery Co., Ltd.
Parameter Item Ultrasonic Lace Sewing Machine(ce qualified) Model Tc-60 Power Source 220v /110v Inout Power 2000w (3 power adjustable) Output Frequency 20khz Working Speed 0-20m/minute Roller Size...
de ropa desechable ultrasonic sewing
$ 1,200 /ud
ChangZhou TengChao Machinery Co., Ltd.
Ultrasonic Sealing Machine Parameter Item Ultrasonic Sealing Machine Model Tc-50 Power Supply 220v 50-60hz Input Power 2000w Output Frequency 20khz Working Speed 0-20m/Minute Roller Size...
Ultrasonic filtro máquina de coser tc-60 modelo sintético
$ 1 /ud
ChangZhou TengChao Machinery Co., Ltd.
Technical Specification Item Ultrasonic Lace Sewing Machine Model tc-60 Power Source 220v /110v Inout Power 2000w (3 power adjustable) Output Frequency 20khz Working Speed 0-20m/minute Roller Size...
Máquina de coser por ultrasonidos con la mejor calidad
$ 1,500 /ud
ChangZhou TengChao Machinery Co., Ltd.
Technical Specification Item Ultrasonic Lace Sewing Machine Model tc-60 Power Source 220v /110v Inout Power 2000w (3 power adjustable) Output Frequency 20khz Working Speed 0-20m/minute Roller Size...
máquina de coser por ultrasonidos tc-100
$ 1,200 /ud
ChangZhou TengChao Machinery Co., Ltd.
Parameter Item Ultrasonic Lace Sewing Machine(ce qualified) Model Tc-60 Power Source 220v /110v Inout Power 2000w (3 power adjustable) Output Frequency 20khz Working Speed 0-20m/minute Roller Size...
Máquina de coser por ultrasonidos para hacer bolsos no tejidos
$ 1,600 /ud
ChangZhou TengChao Machinery Co., Ltd.
Technical Specification Item Ultrasonic Lace Sewing Machine Model tc-60 Power Source 220v /110v Inout Power 2000w (3 power adjustable) Output Frequency 20khz Working Speed 0-20m/minute Roller Size...
Ultrasonic cinta Máquina de Navidad
$ 2,000 /ud
ChangZhou TengChao Machinery Co., Ltd.
Technical SpecificationItem Ultrasonic Lace Sewing MachineModel tc-60Power Source 220v /110vInout Power 2000w (3 power adjustable)Output Frequency 20khzWorking Speed 0-20m/minuteRoller Size...
Coffee capsule filling and sealing machine
A convenir
Ruian Xuanhai Machine Co.,Ltd.
Specifications1.automatic feed coffee capsules/cups 2.automatic fill coffee powder as precise weight 3g, 5g,7g, 3.automatic feed foil,seal equipment has functions as belowing : K cup feeding...
Diodo Laser 980nm del sistema eliminacion de vasculares
A convenir
Medical Beauty
Teoría:Las características de la longitud de onda de 980 nm de absorción son ideales para el tratamiento de los vasos sanguíneos, lo hacen ideal para su aplicación en el cierre del vaso y...
Búsquedas relacionadas con